Chapter2
Alarm
TableofContents
EquipmentAlarm........................................................................................................2-1
CommunicationAlarm..............................................................................................2-24
HandlingAlarm.........................................................................................................2-60
EnvironmentAlarm...................................................................................................
2-68
QoSAlarm...............................................................................................................2-80
2.1EquipmentAlarm
2.1.11001Boardpoweredoff
AlarmProperty
lAlarmCode:1001
lAlarmInformation:Theboardispoweredoff.
lAlarmLevel:Major
lAlarmType:EquipmentAlarm
Sub-codeDescription
lSub-code1:Managementpower
lSub-code2:Servicepower
EffectontheSystem
Theboard'scommunicationlinkisbroken,andservicescarriedbytheboardare
interrupted.
PossibleCauses
Theboardispoweredoff.
HandlingProcedure
1.Checktheadditionalinformationofthealarm.
Ifthealarmhasadditionalinformation,checkwhethertheinsertedboardoftheNEis
inconsistentwiththatconguredatOMCB.
Thefollowingliststheboardtypes(Xrepresentsahexadecimalnumber0~F):
2-1
SJ-20111008094748-008|2012–05–30(R1.1)ZTEProprietaryandCondential