ZXMWNR8250AlarmandNoticationHandlingReference
lTheboardcannotoperateproperly,andtheservicescarriedbytheboardare
interrupted.
PossibleCauses
1.Therunningsoftwareisdamaged.
2.Therunningsoftwareislost.
3.Therunningsoftwaredoesnotexistinthesoftwarepackage(nocorrespondingSWID).
HandlingProcedure
Inthesoftwareversionmanagementwindow,selectMaintenance>Version>IDU,
re-downloadthecorrectsoftwareversionpackage.
2.3.96209Maincontrolsoftwareversionsynchronizationfailure
AlarmProperty
lAlarmCode:6209
lAlarmInformation:Iftheactivemaincontrolboardfailstosynchroizeitssoftware
versionwiththatofthestandbymaincontrolboard,thealarmisreported.
lAlarmLevel:Major
lAlarmType:HandlingAlarm
Sub-codeDescription
lSub-code0:CPUsoftware
lSub-code1:FPGAsoftware
EffectontheSystem
Theactive/standbychangeovercannotbeimplemented.
PossibleCauses
1.Thesoftwareversionofthemaincontrolboardisincorrect.
2.Theharddiskspaceofthestandbymaincontrolboardisinsufcient.
3.Thestandbymaincontrolboardisfaulty.
HandlingProcedure
1.Deletetheredundantlesonthestandbymaincontrolboard.Ifthealarmpersists,go
tostep2.
2.Replacetheboard.
2-66
SJ-20111008094748-008|2012–05–30(R1.1)ZTEProprietaryandCondential