ZXMWNR8250AlarmandNoticationHandlingReference
lAlarmLevel:Minor
lAlarmType:EnvironmentAlarm
Sub-codeDescription
None
EffectontheSystem
Thepowertotheovercurrentboardisturnedoffandtheservicescarriedbythisboardare
completelyinterrupted.
PossibleCauses
TheMPcurrentstatusofthePMboard'sloadischeckedperiodically.Ifover-currentis
detected,thisalarmisreported.
HandlingProcedure
1.Removeandinsertthecorrespondingboard;
2.Replacethecorrespondingboard;
3.ReplacePMboard;
4.Replacethebackplane.
2.4.17405PPovercurrented
AlarmProperty
lAlarmCode:405
lAlarmInformation:ThisalarmisreportedwhenthePPcurrentisoutofrangeand
clearedwhenthecurrentbecomesnormal.
lAlarmLevel:Minor
lAlarmType:EnvironmentAlarm
Sub-codeDescription
None
EffectontheSystem
Thepowertotheover-currentboardisturnedoffandtheservicesprovidedbythisboard
areinterrupted.
PossibleCauses
ThePPcurrentstatusofthePMboard'sloadischeckedperiodically.Ifover-currentis
detected,thisalarmisreported.
2-78
SJ-20111008094748-008|2012–05–30(R1.1)ZTEProprietaryandCondential