Chapter2Alarm
lAlarmLevel:Minor
lAlarmType:EquipmentAlarm
Sub-codeDescription
None
EffectontheSystem
Thisalarmdoesnotaffectanytrafc,butitmaycausedevicetoslowdown.
PossibleCauses
CPUisoverloaded.
HandlingProcedure
Deletethetrafcthatfailstoworkorrestarttheequipment.
OntheLMT ,selectTDM/ETHanddeletetheineffectiveservice.Or,warmstartthe
equipment.
2.1.9134218747RPUApoweredoff
AlarmProperty
lAlarmCode:134218747
lAlarmInformation:ThisalarmisreportedifnopowerissuppliedtoPSportofRPUA
orthepowersupplyisabnormal.
lAlarmLevel:Minor
lAlarmType:EquipmentAlarm
Sub-codeDescription
lSub-code1:RPUA-PS1poweredoff;
lSub-code2:RPUA-PS2poweredoff.
EffectontheSystem
IfRPUA-PS1andRPUA-PS2arepoweredoffsimultaneously,theODUwillbepowered
offandtheradiolinkwillbebroken.
PossibleCauses
1.PS1portorPS2portoftheRPUAboardisnotconnectedtothepowersupply.
2.TheRPUAboardisfaulty.
2-7
SJ-20111008094748-008|2012–05–30(R1.1)ZTEProprietaryandCondential