ZXMWNR8250AlarmandNoticationHandlingReference
2.2.3134217737UASalarmofMS
AlarmProperty
lAlarmCode:134217737
lAlarmInformation:ThisalarmisreportedwhenUASchangeatMSisdetected.
lAlarmLevel:Major
lAlarmType:CommunicationsAlarm
Sub-codeDescription
lSub-code1:Opticalport1ontheRTUBboard;
lSub-code2:Opticalport2ontheRTUBboard.
EffectontheSystem
Thisalarmaffectstrafc.
PossibleCauses
TheuplinkopticalportservicedegradesandcausestheUAStooccur.
HandlingProcedure
1.Checkwhetherthereceivepowerandtransmitpoweroftheopticalmodulearenormal.
lIfyes,gotostep2.
lIfno,replacetheopticalmoduleandensurethattheuplinkequipmentoperates
properly.
2.ReplacetheRTUB.
2.2.4134217738UASalarmofRS
AlarmProperty
lAlarmCode:134217738
lAlarmInformation:ThisalarmisreportedwhenUASchangeatRSisdetected.
lAlarmLevel:Major
lAlarmType:CommunicationsAlarm
Sub-codeDescription
lSub-code1:Opticalport1ontheRTUBboard;
lSub-code2:Opticalport2ontheRTUBboard.
EffectontheSystem
Thisalarmaffectstrafc.
2-26
SJ-20111008094748-008|2012–05–30(R1.1)ZTEProprietaryandCondential