Chapter2Alarm
lAlarmLevel:Critical
lAlarmType:EquipmentAlarm
Sub-codeDescription
SlotID
EffectontheSystem
Thereisnoeffectonservices.
PossibleCauses
1.AboardnotconguredontheLMTisinsertedinaslot.
2.ThePMsoftwareisfaultyanddetectsboardsignalfromaslotwithoutboard.
HandlingProcedure
1.Checkwhethertheboardisinsertedintotheslot.
lIfyes,gotostep2.
lIfno,replacethePMboard.
2.Verifythattheboardneedstobecongured.
lIfyes,conguretheboardthroughLMT.
lIfno,pullouttheboard.
2.1.4134217728Clockreferencesourcelost
AlarmProperty
lAlarmCode:134217728
lAlarmInformation:ThealarmisreportediftheRCUcannotdetecttheclocksignalof
conguredclockreferencesource.
lAlarmLevel:Minor
lAlarmType:EquipmentAlarm
Sub-codeDescription
lSub-code1:RCU1PPS+TODclocklost;
lSub-code2:RCUBITSclocklost;
lSub-code4:Slot3clocklost;
lSub-code5:Slot4clocklost;
lSub-code6:Slot5clocklost;
lSub-code7:Slot6clocklost;
lSub-code8:Slot7clocklost;
lSub-code9:Slot8clocklost;
lSub-code10:RCUNMSclocklost;
lSub-code11:RCUGbEclocklost;
lSub-code12:1588clocklost.
2-3