ZXMWNR8250AlarmandNoticationHandlingReference
PossibleCauses
Thedescriptionofalarmsub-codesareasfollows:
lSub-code0:ODUfailure
lSub-code1:ODUfailure
lSub-code2:ODUfailure
lSub-code3:ODUfailure
lSub-code4:ODUfailure
lSub-code5:ThepoweroftheIFsignalsentfromIDUtoODUislow.
lSub-code6:ThepoweroftheRFsignalreceivedbyODUislow.
lSub-code7:ODUfailure.
lSub-code8:RMUboardorIFcablefailure.
lSub-code9:ODUfailure
lSub-code10:RMUboardorIFcablefailure.
lSub-code11:ODUfailure
lSub-code13:RMUboardfailure
HandlingProcedure
Processthesub-codesasfollows:
lSub-code0:PoweroffandthenrestarttheODU.Ifthealarmpersists,replacethe
ODU.
lSub-code1:PoweroffandthenrestarttheODU.Ifthealarmpersists,replacethe
ODU.
lSub-code2:PoweroffandthenrestarttheODU.Ifthealarmpersists,replacethe
ODU.
lSub-code3:PoweroffandthenrestarttheODU.Ifthealarmpersists,replacethe
ODU.
lSub-code4:ReplacetheODU.
lSub-code5:PoweroffandthenrestarttheODU.Ifthealarmpersists,useashorter
IFcable.
lSub-code6:EnsurethattheODURxfrequencyonlocalsitematchesODUTx
frequencyonremotesite.Ifthealarmpersists,increaseremoteODUtransmitpower.
Ifthealarmstillremains,replacetheODU.
lSub-code7:ReplacetheODU.
lSub-code8:ReplacetheIFcable.Ifthealarmpersists,replacetheRMUboard.
lSub-code9:ReplacetheODU.
lSub-code10:ReplacetheIFcable.Ifthealarmpersists,replacetheRMUboard.
lSub-code11:ReplacetheODU.
lSub-code13:ReplacetheRMUboard.
2-48
SJ-20111008094748-008|2012–05–30(R1.1)ZTEProprietaryandCondential