ZXR102900ESeriesCongurationGuide
b.Notethechuteandwhethertherelatedwireisloosen.Ifitisloose,adjustit.
3.Cleantheswitch
Notetheclothshouldnotbetoowetandtheoperationcannotaffecttheinterface.
4.Thebackupofthealarminformation,thebackupofstatisticsinformation,thebackup
ofcongurationinformation
MaintenancePeriod
ThemaintenanceperiodofEthernetswitchisshownasT able6-1.
Table6-1MaintenancePeriodofEthernetSwitch
No.MaintenanceTestItemTestPeriod
1SwitchrunningstateDay
2
Equipmentroomtemperatureandhumiditycheck
andpowercheck
Day
3
Thetelecommunicationstatebetweenswitchand
thedevice
Day
4
Whethertherelatedserviceisnormally
implemented
Day
5OrdinaryproblemmonthlysummaryMonth
6
Ordinarymaintenanceexperiencemonthly
summary
Month
7EquipmentroomcleaningMonth
8SwitchcleaningMonth
9YearlysummaryYear
10
Monitoringroomdevicefullmaintenanceand
check
Year
6.2VirtualLineDetection
VCTappliesTDRtorealizethediagnosisoftheline.Itcandiagnosethefaultstateofthe
line,suchasOpen,Short,ImpedanceMismatchandGoodtermination.Alsoitcanuse
theexperienceformulatocalculatethelocationofthefaultline.
Usetheshowvctport<1-28>commandtochecktheVCTdetectionresultofthespecied
port.
Example1
zte(cfg)#showvctport1
CableTestResultforPort1
6-2
SJ-20120409144109-002|2012-07-02(R1.0)ZTEProprietaryandCondential