Configuration
IM/265Gx/Ax-EN-07 265Gx, 265Ax 57
How the percentage value is shown on the LCD display
Position Display
1st line Percentage value, limits: -25 … 125 %,
2 decimal places
2nd line
1st digit:
Transmission function (see previous table)
2nd digit:
Write protection (see previous table)
7th digit:
%
Bar 2 % increments, from -2 … 100 %,
no hysteresis
7.5.2 Menu structure
The parameters are structured in the form of a menu. The menu consists of a maximum of three
levels.