Technical data
109
AGPS-11C
Nominal input voltage 115...230 V AC ±10%
Nominal input current 0.1 A (230 V) / 0.2 A (115 V)
Nominal frequency 50/60 Hz
Max. external fuse 16 A
X1 terminal sizes 3 x 2.5 mm
2
Output voltage 15 V DC ±0.5 V
Nominal output current 0.4 A
X2 terminal block type JST B4P-VH
Ambient temperature 0...50 °C
Relative humidity Max. 90%, no condensation allowed
Dimensions (with enclosure) 167 x 128 x 52 mm (Height x Width x Depth)
Weight (with enclosure) 0.75 kg
Approvals C-UL, US listed
Ambient conditions
Environmental limits for the drive are given below. The drive is to be used in a heated,
indoor, controlled environment.
Operation
installed for stationary use
Storage
in the protective package
Transportation
in the protective package
Installation site altitude 0 to 4000 m (13123 ft) above
sea level [above 1000 m
(3281 ft), see section
Derating]
--
Air temperature -15 to +50 °C (5 to 122 °F).
No frost allowed. See section
Derating.
-40 to +70 °C (-40 to
+158 °F)
-40 to +70 °C (-40 to
+158 °F)
Relative humidity 5 to 95% Max. 95% Max. 95%
No condensation allowed. Maximum allowed relative humidity is 60% in the presence of
corrosive gases.
Contamination levels
(IEC 60721-3-3, IEC 60721-3-
2, IEC 60721-3-1)
No conductive dust allowed.
Boards without coating:
Chemical gases: Class 3C1
Solid particles: Class 3S2
Boards with coating:
Chemical gases: Class 3C2
Solid particles: Class 3S2
Boards without coating:
Chemical gases: Class 1C2
Solid particles: Class 1S3
Boards with coating:
Chemical gases: Class 1C2
Solid particles: Class 1S3
Boards without coating:
Chemical gases: Class 2C2
Solid particles: Class 2S2
Boards with coating:
Chemical gases: Class 2C2
Solid particles: Class 2S2
Atmospheric pressure 70 to 106 kPa
0.7 to 1.05 atmospheres
70 to 106 kPa
0.7 to 1.05 atmospheres
60 to 106 kPa
0.6 to 1.05 atmospheres
Vibration (IEC 60068-2)* Max. 1 mm (0.04 in.)
(5 to 13.2 Hz),
max. 7 m/s
2
(23 ft/s
2
)
(13.2 to 100 Hz) sinusoidal
Max. 1 mm (0.04 in.)
(5 to 13.2 Hz),
max. 7 m/s
2
(23 ft/s
2
)
(13.2 to 100 Hz) sinusoidal
Max. 3.5 mm (0.14 in.)
(2 to 9 Hz),
max. 15 m/s
2
(49 ft/s
2
)
(9 to 200 Hz) sinusoidal
Shock (IEC 60068-2-29) Not allowed Max. 100 m/s
2
(330 ft./s
2
),
11 ms
Max. 100 m/s
2
(330 ft./s
2
),
11 ms
Free fall Not allowed 250 mm (10 in.) for weight
under 100 kg (220 lb)
100 mm (4 in.) for weight
over 100 kg (220 lb)
250 mm (10 in.) for weight
under 100 kg (220 lb)
100 mm (4 in.) for weight
over 100 kg (220 lb)
*Note: For frame sizes R2 to R4 with panel option maximum allowed vibration is 3 m/s
2
. For higher vibration use the
RPMP kit. See Control Panel Mounting Platform Kit (RPMP) Installation Guide [3AFE64677560 (English)].
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ACS800-U4 and is the answer not in the manual?

ABB ACS800-U4 Specifications

General IconGeneral
BrandABB
ModelACS800-U4
CategoryController
LanguageEnglish

Related product manuals