- 58 -
000833BG
5 - Installation
It is the installer’s responsibility to
choose an appropriate number
and distribution of attachment
points. The choice must be ba-
sed on the type of support (wall,
frame or other support), the type
of anchors to be used, and their
ability to support 4 times the in-
verter’s weight (4x125Kg=500Kg
for all models).
Attach the bracket
03
to the sup-
port with at least 6 attachment
screws (shown in RED) or at le-
ast 6 frame xing bracket for fra-
me mounting (shown in BLUE).
Depending on the type of anchor
chosen, drill the required holes to
mount the bracket
03
. The pictu-
res shown the recommended mi-
nimum xing point depending to
the type of support.
In case of use of “frame
xing brackets” (see side
picture as example) it will
be possible to x the bra-
cket to the frame structure
without drill any additional
holes.
Fix the bracket
03
to the support.
Wall/Floor mounting
minimum xing points
Frame mounting (3 supports)
minimum xing points
Frame mounting (2 supports)
minimum xing points
Frame xing brackets