50 Technical data
DC input fuse recommendations
The DC inputs are designed for Bussmann PV fuses. The table lists the mechanically
suitable fuses for different input options.
1) Total number of input in the inverter. Applicable for 1645kW and 1732kW types.
2) Fuses require special mechanics which are not compatible with other fuse body sizes.
Number of inputs
(1
X = Standard fuses
O = Optional fuses
Fuses in + and - Fuses only in + or -
16 18 20 22 24 16 18 20 22 24 Type
PV-160AF2
X X X X PV-200AF2
X X X X PV-250AF2
X X PV-315AF3
PV-355AF3
PV-400AF3
Dimensions of the recommended fuses (mm). 1 mm
Size [mm] A B C D E F
2 91.3 81.8 24 61 77 Thread hole
M10,
9.5 mm