52 Technical data
Free space requirements
For cabinet dimensions, refer to Dimension drawings on page 45.
Adequate free space above the inverter has to be reserved for installation and cooling.
Required free space in from of the inverter for door opening, power module and LCL filter
replacement is 850 mm.
Cooling data
Required cooling air flow
Main circulation: 8000 m
3
/h (4720 ft
3
/min)
1 ISU cabinet 3900 m
3
/h
AC cabinet: 1300 m
3
/h
DC cabinet: 615 m
3
/h
Optional DC cabinet: 245 m
3
/h
AUX cabinet: 260 m
3
/h
Total: 10000 m
3
/h (5880 ft
3
/min)
Terminal and lead-through data for the AC power
connections
Cable lead-throughs 30 pcs
Cable outer diameter 8...60 mm/lead-through
Tightening torques: *M12 70 Nm
Terminal and lead-through data for the DC power
connections
16 DC inputs Cable lead-throughs 32 pcs
Cable outer diameter 5...60 mm/lead-through
Tightening torques: *M12 70 Nm
24 DC inputs Cable lead-throughs 48 pcs
Cable outer diameter 5...60 mm/lead-through
Tightening torques: *M12 70 Nm

Table of Contents

Other manuals for ABB PVS800-57B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB PVS800-57B and is the answer not in the manual?

ABB PVS800-57B Specifications

General IconGeneral
BrandABB
ModelPVS800-57B
CategoryInverter
LanguageEnglish

Related product manuals