3.3.2 Fault code 01.1.00 -
Fault code DIN brief description Cause Consequences Remedy
01 = EDC engine control
0, 1, 2 = fault weighting (0 = heavy, 1 = medium; 2 = light)
01... = sequential number
The sorting of the error code is based on the serial number
01.1.01
B055 foot throttle sensor
Signal too high,
Signal to low,
No signal for longer than 2000 ms
TMS is switched off Circuit diagram
01.1.02
A169 engine control unit, ECU (EDC 17)
EDC message (actual engine
speed) timeout or declared faulty,
CAN connection interrupted,
EDC not sending messages
Driving possible in
emergency operating
mode
01.1.03
B055 foot throttle sensor
For A050 basic control ECU
For A169 engine ECU (EDC17)
No concordance
Circuit diagram
Calibration code "4005"
01.1.04
A050 basic control unit ECU
Checksum error
TMS
No TMS drive
possible
EOL
programming
01.1.06
A050 basic control unit ECU
Memory in EXT could
not be reserved, EXT fault
TMS non-operable
01.1.07
A169 engine control unit, ECU (EDC 17)
Checksum
Incorrect engine parameters
Travel in emergency mode
possible
EOL
programming
01.1.0E
A050 basic control unit ECU
The tractor is not parametrised as
an ABS tractor. However, an ABS
control unit was detected
Wheels can lock in spite
of ABS
EOL
programming
3. Faults and remedy
130 Maintenance
530.020.020.011 Rev.A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AGCO FENDT 1046 Vario S4 and is the answer not in the manual?

AGCO FENDT 1046 Vario S4 Specifications

General IconGeneral
BrandAGCO
ModelFENDT 1046 Vario S4
CategoryTractor
LanguageEnglish

Related product manuals