EasyManuals Logo
Home>Alto-Shaam>Oven>Vector VMC-H4H

Alto-Shaam Vector VMC-H4H Service Manual

Alto-Shaam Vector VMC-H4H
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #69 background imageLoading...
Page #69 background image
TROUBLESHOOTING
Ve ct or H Se ries S ervice Ma nual MN -4 654 4 Rev 0 1 11/19
69
How to Calibrate a Chamber Thermocouple
Before you begin The oven must be connected to electric power.
Make sure you have a multimeter with a thermocouple attachment.
Make sure the jet plates are installed.
You will need to know the service pass code.
Procedure To calibrate a chamber thermocouple, do the following.
Step Action
1. Touch the menu icon a. The user menu screen displays.
2. Touch the service icon b. The enter pass code screen displays.
Continued on next page
NOTICE
Do not operate the oven in a cooking mode for an extended
period of time with the top panel removed. Damage to the
electronics may occur without adequate cooling airflow.
An auxiliary air fan must be used if the oven is to be operated
in a cooking mode for an extended period of time with the top
panel removed.
VMC-TS-006259
a
VMC-TS-008129
b

Table of Contents

Other manuals for Alto-Shaam Vector VMC-H4H

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alto-Shaam Vector VMC-H4H and is the answer not in the manual?

Alto-Shaam Vector VMC-H4H Specifications

General IconGeneral
BrandAlto-Shaam
ModelVector VMC-H4H
CategoryOven
LanguageEnglish

Related product manuals