EasyManuals Logo
Home>Ariel>Air Compressor>JGQ

Ariel JGQ User Manual

Default Icon
178 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #100 background imageLoading...
Page #100 background image
FOR MODELS: JGI, JGM, JGN, JGP AND JGQ SECTION 4 LUBRICATION
PAGE 4-42 9/08
3. Total oil consumption of compressor lube system
4. Daily and total lost dollars (US) for over lubricating.
5. Total divider block cycles,
6. Total run time of the compressor.
The Proflo PF1 monitor can store one year’s worth of operating data in a first in, first out
(FIFO) memory.
The FFT software can be used to reset Proflo PF1 memory. The reset time and date is re-
corded to the Proflo PF1's Electrical Erasable Programmable Read Only Memory, (EE-
PROM).
To start the download push the SET button then push the mode button 5 times until the LCD
displays SEND DATA? then push the SET button. Set the FFT software to accept the Proflo
PF1 data and hold the handheld computer in a position to communicate with the IrDA port.
The LCD will display SENDING. If there is no devise to receive the data the LCD will display
FAILURE and after 30 seconds return to LAST and AVG default display.
The software provides for conversion to Microsoft Excel files for trending and graphing.
Hand held Palm operating system computers are available at most electronic or discount
stores or on the Internet.
For more details on this product and other Proflo PF1 accessories, see the Ariel web at
www.arielcorp.com and/or contact your packager or Ariel.
Proflo PF1 Setup Alarm Time and Mode:
To setup the Alarm contact output operation, red wires, first push the SET button. Push mode
button six (6) times until LCD displays SETUP?. Push SET button and the LCD will scroll to
1. SET ALARM TIME. Push and release set button to change alarm-shutdown from 30 to 240
seconds. When the compressors leave Ariel this time is set to 120 seconds. Ariel recom-
mends setting the alarm time to 2 times the normal cycle time rounded up to the near-
est 5 seconds. This time should not be less than 30 seconds or greater than 180
seconds. Normal design cycle time can be found on a nameplate on the lube oil pump box.
The control system must be configured to shutdown the compressor for a no-flow indication.
Push the mode button, two (2) more times and the LCD will scroll to SET ALARM MODE.
Push set button to toggle from N/O normally open or N/C normally closed. Ariel recom-
mends using the NC operation.
After wiring mode is set the monitor will automatically return to the LAST and AVG display in
30 seconds.