APPLIANCE PROTECTION DEVICES
Appliance shut-off conditions
Theapplianceisprotectedfrommalfunctionsbymeansof
internalchecks,whichstopstheappliancefromoperating
ifnecessary.
Intheeventoflockoutseetablebelow.
Table failures
Description Checks to make
Batteryexhausted
RED L.E.D. Fixed
Replacebattery
Nohotwaterproduced
Theappliancewon’tstart
- Ensurethatthegasisolationvalveisopen
- Ensurethattheinletwaterisolationvalveisopen
- VerifypositionohftheON/OFFbutton
- Check/Replacebatteries
Lowtemperaturewater. VerifythepositionoftheDHWtemperatureKnobandsetthedesiredtemperature.
TheburnerswitchOFFoutduring
use.
- Safetyshut-offforoverheating.
Restartthedeviceafter10minutes.Ifthefaultreappears,contactanauthorizedtechnician.
- TemporaryShut-Offduetodefectiveuegasdischarge.
Restartthedeviceafter
10minutes.Ifthefaultreappears,contactanauthorized
technician.
Makesuretheuepipeoutletisproperlyinstalled
Checkiftheuepipeispartiallyobstructed.
Reducedwaterowrate.
- Lowwatersupplypressure.
- Watertapsormixerdirty.
- Presenceoflimescaleintheheatexchanger
IF THE APPLIANCE WON’T START AGAIN OR
STOPS REPEATEDLY, ONCE YOU’VE CARRIED
OUT THE RELEVANT CHECKS, TURN OFF THE
DEVICE, CLOSE THE GAS VALVE, REMOVE
THE BATTERIES AND CONTACT A QUALIFIED
TECHNICIAN.
SHOULD THE CAUSE OF THE BLOCK NOT
BE ELIMINATED, DO NOT ACTIVATE THE
APPLIANCE.
ALL REPAIRS, WHICH SHOULD ONLY BE
PERFORMED USING ORIGINAL SPARE PARTS,
SHOULD BE CARRIED OUT BY A QUALIFIED
PROFESSIONAL.