20
EASY MODE
Once the radiator is set into the Easy Mode the radiator will only allow the user to raise and
lower the temperature setting.
There is no access to the clock, mode or configuration changes and no keyboard lock, just the
heating icon showing if the radiator is currently heating and the current room temperature.
Only the standby key, the and keys are operational.
The configuration values are set as shown below and cannot be modified:
1 - Brightness level at rest: 10 %
2 - Maximum brightness Time: 30 seconds
3 - Open Window: OFF
The radiator temperature set-point is adjustable with the and keys between 12ºC and
30ºC, in steps of 0.5ºC
ERROR NOTIFICATIONS
There are 2 types of errors that the electronics can detect; if an error is
detected one of the codes below will be shown on the screen until it is resolved.
ERROR CODE DESCRIPTION
ERROR1 Failure in microcontroller, EPROM or other PCB component
ERROR2 Failure of the NTC probe (e.g. disconnected, short-circuited, etc.)
When recovering from an error, the radiator will always return to Stand-by mode, the radiator
will not retain any previous mode or state.
If the radiator goes to Stand-by without any specific reason, it may have recovered from an
error.