The Lifestyle radiator must be connected to the mains supply (230V~50Hz.). It is recommended
to install a switched spur for each heater. In addition, the following warnings must be
considered:
-The electric radiator should not be located underneath a light switch where you need to
stretch over the heater to reach or operate the switch.
-The electric line should be protected with a high sensitivity differential device (RCBO).
-It is necessary to disconnect the power from the fixed wiring before installation.
Connecting wires:
Brown: Live
Blue: Neutral
Yellow-Green: Earth
The connecting wires must be of the appropriate cross section, with regard to the length of
cable, type of cable and power rating of the appliance.
The appliance must be connected into a fused connecting box fitted with an appropriate sized
fuse for the radiator ā see Technical Data on Page 21.
We recommend that the connecting box is positioned 10cm to the right of the appliance and at
15cm above the floor.
According to regulations, the appliance must be connected to the power supply by means of
an all-pole circuit breaker with a contact gap of at least 3mm or by a thermal-magnetic circuit
breaker. It is recommended to install the heaters on a circuit protected by an RCBO