EasyManuals Logo
Home>Atlas Copco>Air Compressor>G 160 VSD

Atlas Copco G 160 VSD User Manual

Atlas Copco G 160 VSD
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #60 background imageLoading...
Page #60 background image
Reference Name
1 Alarm
2 Service
3 Automatic operation
4 Voltage on
5 Enter
6 Escape
7 Scroll keys
8 Stop
9 Start
Procedure
Step Action
1 Press the start button. The compressor starts running in unloaded condition. The
automatic operation LED lights up.
2 Approx. 10 seconds later (programmable), the compressor starts running loaded.
5.4 During operation
Warning
The operator must apply all relevant Safety precautions.
The operator should immediately stop the machine in case of oil leaks internally in the
machine as well as externally and consult a competent technician to resolve the cause.
The machine should not be restarted before the problem has been remedied.
The load cycle of the compressor must be limited to maximum two cycles per minute.
Instruction book
58 APF221384

Questions and Answers: