Period Running hours Operation
When displayed -- Carry out service action according to the displayed service plans.
When operating in a dusty atmosphere, inspect the air filters more frequently.
Use always Atlas Copco filters.
The separator element must also be replaced when the pressure difference over the
element exceeds 0.8 bar (12 psi). Check the pressure drop when the compressor is
running loaded and preferably with a stable working pressure.
Damaged flexibles must be replaced immediately.
Service agreements
Atlas Copco Customer Centres have a range of service agreements to suit your needs:
• An Inspection Plan
• A Preventive Maintenance Plan
• A Total Responsibility Plan
Contact your Customer Centre to set up a tailor-made service agreement. It will ensure optimum
operational efficiency, minimize downtime and reduce the total life cycle costs.
Service plan
A number of service operations are grouped (called Level A, Level B, Level C...). Each level
stands for a number of service actions to be carried out at the time intervals programmed in the
Elektronikon regulator.
When a level is reached, a message will appear on the screen. After carrying out all service
actions, the interval timers must be reset using the “Reset” key in the “Service” menu. Consult
your Atlas Copco Service Centre.
6.2 Motors
Warning
• Stop the compressor and switch off the voltage. The operator must apply all
relevant Safety precautions.
• Never mix greases of different brands or types.
• Motor bearing maintenance is crucial to avoid motor damage.
Maintenance is limited to applying the motor grease mass at the interval that is stated on the
motor bearing data plate attached to the motor.
Contact your local Atlas Copco customer center in following cases:
• If not all the necessary data are present on the bearing plate.
• If the correct lubrication method is not clearly stated in the general instruction book.
• If the maximum ambient/bearing temperature differs from the one mentioned on the motor
data plate.
Instruction book