EasyManuals Logo
Home>Atlas Copco>Air Compressor>G 160 VSD

Atlas Copco G 160 VSD User Manual

Atlas Copco G 160 VSD
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #74 background imageLoading...
Page #74 background image
Service panel of the cooler (1), air-cooled cooler
Step Action
1 Open the service door at the cooler side.
2 Remove the service panel (1) at the cooler side.
3 Remove any dirt form the coolers with a fibre brush, brush in the direction of the fins.
Also remove any dirt from the fans.
4 Clean the coolers with an air jet in the reverse direction to normal flow. Use low
pressure air; if necessary, the pressure may be increased up to 6 bar (e) (87 psig).
5 If it is necessary to clean the coolers with a cleaning agent, consult Atlas Copco.
6 Mount the service panel.
7 Close the door.
7.3 Safety valve
Warning
Stop the compressor and switch off the voltage. The operator must apply all relevant
Safety precautions.
Never run the compressor without safety valves.
No adjustments are allowed.
Instruction book
72 APF221384

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco G 160 VSD and is the answer not in the manual?

Atlas Copco G 160 VSD Specifications

General IconGeneral
BrandAtlas Copco
ModelG 160 VSD
CategoryAir Compressor
LanguageEnglish

Related product manuals