3 Elektronikon™ Swipe controller
3.1 Controller
The Elektronikon™ Swipe controller
Introduction
The controller has following functions:
• Controlling the unit
• Protecting the unit
• Monitoring components subject to service
• Automatic restart after voltage failure (ARAVF)
Automatic control of the unit
The controller maintains the net pressure between programmable limits by automatically loading
and unloading the unit.
A number of programmable settings, e.g. the unloading and loading pressures, the minimum stop
time and the maximum number of motor starts are taken into account.
The controller stops the unit whenever possible to reduce the power consumption and restarts it
automatically when the net pressure decreases. If the expected unloading period is too short, the
unit is kept running to prevent too short standstill periods.
A number of time based automatic start/stop commands may be programmed. Take into
account that a start command will be executed (if programmed and activated), even after
manually stopping the unit.