8 Problem solving
Warning
If the compressor is stopped because the supply voltage is interrupted, please
be aware that it will restart automatically when the power is restored! See also
section Safety precautions - general.
Before carrying out any maintenance, repair work or adjustment, stop the compressor
(see section Stopping). Wait until the compressor has stopped (approx. 30 seconds),
press the emergency stop button and switch off the voltage. Close the air outlet valve,
open the manual drain valve. Depressurise the compressor by opening the oil filler
plug (FC) one turn.
For location of components, see sections Introduction , Condensate system and Initial
start-up .
Open and lock the isolating switch.
The air outlet valve can be locked during maintenance or repair as follows:
Close the valve.
Remove the screw fixing the handle with the wrench delivered with the compressor.
Lift the handle and turn it until the slot of the handle fits over the blocking edge on the
valve body.
Fit the screw.
The operator must apply all relevant Safety precautions.
Faults and remedies, compressor
On compressors equipped with an Elektronikon® Graphic controller, if the alarm LED is lit or flashes, consult
sections Event history menu or Service menu.
Condition Fault Remedy
Compressor starts running, but
does not load after a delay time
Solenoid valve out of order Replace valve
Inlet valve stuck in closed position Have valve checked
Leak in control air tubes Replace leaking tubes
Minimum pressure valve leaking
(when net is depressurised)
Have valve checked
Compressor does not unload,
safety valve blows
Solenoid valve out of order Replace valve
Inlet valve does not close Have valve checked
Condensate is not discharged from
condensate separator during
loading
Discharge tube clogged Check and correct as necessary
Float valve malfunctioning
(condensate drain, units without
dryer)
Remove float valve assembly,
clean and check
Compressor air output or pressure
below normal
Air consumption exceeds air delivery
of compressor
Check equipment connected
Choked air filter element Replace filter element
Solenoid valve malfunctioning Replace valve
Leak in control air tubes Replace leaking tubes
Inlet valve does not fully open Have valve checked
Instruction book
2920 7104 10 85

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco GA 7 VSD MED and is the answer not in the manual?

Atlas Copco GA 7 VSD MED Specifications

General IconGeneral
BrandAtlas Copco
ModelGA 7 VSD MED
CategoryAir Compressor
LanguageEnglish

Related product manuals