Power Focus 600 EN
© Atlas Copco Industrial Technique AB - 9836 4954 01
35
Parameter Description Default value
<Manual> Length of time to perform the soft
stop.
200 ms
Common procedures
This chapter describes commonly used procedures and functions in the Power
Focus 600 controller. Each tutorial gives a step by step instruction on how to
solve the problem described or the task to be performed.
Setting up a basic tightening
This tutorial describes how to set up a basic tightening using the TurboTight
strategy. You will learn how to activate your tightening program (Pset) and how
to set the target torque with which the tool will tighten the bolt.
Scenario
The task is to set up the controller to perform a tightening that clamps together
two joint members with a bolt and nut to the specified torque 30 Nm using the
default tightening strategy TurboTight.
Required hardware Power Focus 600, Power tool
Configuring the Pset
1. On the Main menu, choose Tightening and press
OK.
2. Go to the Pset that you wish to use. Make sure the
Pset is not in use by other users and that you are
allowed to configure it. In this example we will
use Pset 1.
3. In the Target torque text box, press OK to edit
the target torque value and enter the value 30 us-
ing the alphanumeric keypad. Press OK to store
the value.
4. Select TurboTight as configuration strategy.
When changing from another strategy to Tur-
boTight you have to decide if to
• Reset and recalculate all parameters except
Target torque, and use parameter values based
on the built-in parameter rules.
• Manually edit the parameters and set correct
parameter values.