- 44 -
TOPPING UP WITHOUT DRAINING FROM THE COOLING SYSTEM
The quantity of PARCOOL EG Concentrate to be topped up can be estimated with the following formula and/or graph:
Corrections concentrate in measured system towards 50% volume by using PARCOOL EG Concentrate
14
33
33 17 14 50 4,8
50- = =*/
4
0,0
0,5
1,0
1,5
2,0
2,5
3,0
3,5
4,0
4,5
5,0
5,5
6,0
5678910111213141516
1
2
3
4
5
Example:
Total volume coolant =
Measured concentration =
In case of expansion tank at low level, this quantity is to
be filled without draining from the cooling system.
1 Refractometer indication -20° C (-4° F) (33%)
2 Refractometer indication -22° C (-7.6° F)
3 Refractometer indication -25° C (-13° F)
4 Refractometer indication -30° C (-22° F)
5 Refractometer indication -36° C (-32.8° F)
Engine coolant capacity (liter)
Top-up volume PARCOOL EG Concentrate without drainage
Top-up volume (liter)
PN: 1604 8159 01
Liter
Vol %
Liter PARCOOL EG Concentrate
DD6.book Page 44 Monday, November 10, 2014 11:25 AM

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco XAHS 186 Dd and is the answer not in the manual?

Atlas Copco XAHS 186 Dd Specifications

General IconGeneral
BrandAtlas Copco
ModelXAHS 186 Dd
CategoryAir Compressor
LanguageEnglish

Related product manuals