5.4.2 MP-124 Rev. E
MP-124 Rev. E provides serial interface through the RJ-45 port located on the rear panel:
Cable adapter: straight-through RJ-45 to DB-9 cable (not supplied)
Figure 5-27: RJ-45 to DB-9 Serial Cable Adapter
Connector pinouts:
Table 5-2: RJ-45 to DB-9 Serial Cable Connector Pinouts
RJ-45 DB-9 Female
1 8
2 6
3 2
4 5
5 5
6 3
7 4
8 7
To connect MP-124 Rev. E to a computer for serial communication:
1. Connect the RJ-45 connector, at one end of the cable adapter, to the device's RJ-45
port labeled ETHERENT, located on the rear panel.