...a product of BEKA
7.6 Error messages and warnings
The integrated control unit GIGA-multitronic differs between error messages and warnings. Both are shown by a blinking
display of the control unit.
If an error message is available, the integrated control unit switches off the pump. The error cOffe must be solved
immediately.
If an error is available, the pump continues to operate. The warning cOffe must be solved .as soon as possible
Some errors or warnings delete itself (e.g. level error), when the cOffe has been solved. Errors and
warnings that do not delete itself (e.g. pulse error at distributor) must be reset by initiating an
intermediate lubrication after the error cOffe has been solved.
7.6.1 Read out of error or warning when using a progressivee and single line lubrication system
Error and warnings are shown by a blinking display as well as with a plain text in the lower display line.
· Press OK to see errors and warnings
Fig. 14:
(Example: progressivee lubrication system)
If more errors or warnings occur or if an error and warning occur at the same time, a small arrow is shown at the bottom
and / or at the top of the display center.
You can scroll by means of the control buttons downwards or upwards respectively to the right or to the left.
Fig. 15:
ERROR:
empty level
progressive
state
cycle time
lubr. time
ERROR
WARNING
error
00:00:15
0:05:00
Note!
© BEKA 201 All rights reserved5!
16