6.1.1 Motor cable
The motor cable can be supplied in the following
lengths:
Cable length Diameter Order number
5 m 0.75 mm
2
62501316005
10 m 0.75 mm
2
62501316010
15 m 0.75 mm
2
62501316015
20 m 0.75 mm
2
62501316020
30 m 0.75 mm
2
62501316030
Special lengths in gradations of 1.0 m are available
on request.
NOTE
Preferred length: 10 m
6.1.2 Mains filter
A mains filter is inserted in the mains cable for the
purpose of radio shielding as per VDE 0871/limit
class A.
Ambient conditions
Storage temperature -25°C to +70°C
Operating temperature 0°C to 55°C
Humidity class, components F acc. to DIN 40 040
Humidity class, tested to IEC 68 part 2-3 at:
Air temperature +40°C, +2°C
Relative humidity 93%, +2%, -3%
non-condensing
6.1.3 Signal cable signal interface 1
The signal cable for the IP 247 with connectors at
both ends can be supplied in the following lengths:
Cable length Order number
0.5 m 62501413005
1.5 m 62501413015
5 m 62501413050
10 m 62501413100
The signal cable for the IP 267 with connectors at
both ends can be supplied in the following lengths:
Cable length Order number
0.5 m 62501414005
1.5 m 62501414015
5 m 62501414050
10 m 62501414100
The signal cable for signal interface 1 with connec-
tors only at equipment end can be supplied in the
following lengths:
Cable length Order number
0.5 m 62501415005
1.5 m 62501415015
5 m 62501415050
10 m 62501415100
6.1.4 Signal cable signal interface 2
N
→
→
→
L N PE
L1 N1 PE
L
Figure 6-2 Mains filter
Appendix