5
HTE402559 42/47
Code Name of Code Error and Remedy
E-oL
Trip by Over Current
The error is annunciated when output current excesses
the rated current. Turn power off and check the drive
frequency and model of the drive unit.
E-SU
Abnormal voltage for Over Flow Sensor
The error is annunciated when control power decreases.
Check any short circuit and fault polarity.
E-HU
Abnormal input voltage/High voltage
The error is annunciated when the input voltage is far
off the rated voltage. Check the voltage.
E-LU
Abnormal input voltage/Low voltage
E-in
Fault connection on the input terminals
The error is annunciated w
hen power source and load are
connected inversely. Check the wiring.
E-m
Mode Error
The error is annunciated
when the operation mode set
on the
Speed Change Signal 1, 2 and 3 is different from
that on the Speed Change Signal 0. Follow the Speed
Change Signal 0.
1.Turn power off
2.Pressing “SAVE”
button turn power on.
3.Initializing
4.Initialized and
release “SAVE” button
“-X.X-“
means
program version.
The data selected
by setting dial
appears on the
display.
How to initialize the settings
SAVE
Error Code

Questions and Answers: