AMC2 Modular
Controller
UL Requirements | en 47
Bosch Access Systems GmbH 2018-09 | AMC2-4W_UL |
5.1.2 Monitor
– Graphical adapter with 1024x768 resolution and 32k colors
– Resolution support:
– 1024 by 768
– 1280 by 1024
– 1920 by 1080
– 2560 by 1080
5.1.3 Printer
Standard laser printer suited for graphics.
5.2 UL 294 Level Descriptions
The following UL 294 levels apply:
– ACCESS CONTROL DESTRUCTIVE ATTACK LEVEL I - An
access control product intended for, but not limited to, a
controlled area that is not required to meet the destructive
Attack Test.
– ACCESS CONTROL LINE SECURITY LEVEL I - An access
control product with no communication line security.
– ACCESS CONTROL ENDURANCE LEVEL IV - An access
control product shall operate as intended at rated voltage
and current for 100,000 cycles of intended operation.
– ACCESS CONTROL STANDBY POWER LEVEL II – An access
control product for units employing Model APS-PSU-60
Power Supply for 12 VDC and 24 VDC Mode. Level II
operates for 30 minutes.