EasyManuals Logo
Home>Canon>Security Camera>VB-H43

Canon VB-H43 User Manual

Canon VB-H43
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #48 background imageLoading...
Page #48 background image
48
Administrator Password
(1) [Password]
Set the administrator password. Up to eight (single-
byte) ASCII characters (space or printable
characters) can be used. The factory default setting is
“camera”. If the Admin Viewer, Admin Tools, etc., are
connected, terminate the connection before changing
the password.
(2) [Confirm Password]
Enter the same password as above for confirmation.
LAN
(1) [LAN Interface]
Select [Auto], [Full Duplex] or [Half Duplex]. Normally
[Auto] is used.
(2) [Maximum Packet Size]
Enter the maximum transmission unit. Normally there
is no need to change the default setting of 1500.
Note
When using optical fiber or ADSL, setting the maximum packet
size to a slightly lower value may increase sending efficiency.
IPv4
(1) [IPv4 Address Setting Method]
Select [Manual] or [Auto (DHCP)] in the address
setting method. If [Manual] is selected, directly enter
the values according to the environment in which the
camera is used. If [Auto (DHCP)] is selected, the value
automatically acquired from the DHCP server will be
entered in [IPv4 Address], [Subnet Mask] and [IPv4
Default Gateway Address].
(2) [IPv4 Address]
If [Manual] is specified in (1), enter a fixed IP address.
(3) [Subnet Mask]
If [Manual] is specified in (1), enter the designated
subnet mask values for each network.
(4) [IPv4 Default Gateway Address]
Enter an appropriate value if [Manual] is specified in
(1). Be sure to set when connecting the camera to a
different subnet from that of the viewer.
[Network]
Setting Administrator Password, LAN, IP Address, DNS, etc
The following can be set here.
Administrator Password
Set the administrator password.
•LAN
Set the IP address and other items needed to
establish a LAN connection.
•IPv4
Set IPv4 address.
•IPv6
Set IPv6 address.
•DNS
Set the name server address, host name and
DDNS registration.
SNMP
Configure the necessary settings to use SNMP.
Important
To ensure system security, be sure to change the
administrator password. Do not forget the new password.
Press the reset switch to restore factory default settings if you
have forgotten the administrator password (p. 172). Note,
however, that this will reset all camera settings to factory
default settings except for date and time.
Important
The camera may become inaccessible from the active web
browser if [LAN Interface] or [Maximum Packet Size] settings
are changed. Check beforehand the precautions in
“Important” in “[Reboot Item] Setting Items Requiring
Rebooting” (p. 83).
Set [Maximum Packet Size] to 1280 or greater if using IPv6.

Table of Contents

Other manuals for Canon VB-H43

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Canon VB-H43 and is the answer not in the manual?

Canon VB-H43 Specifications

General IconGeneral
TypeIP security camera
PTZ controlYes
Processor modelCanon DIGIC DV III
Placement supportedIndoor
Light exposure modesAperture priority AE, Auto, Manual, Shutter priority AE
Connectivity technologyWired
Form factorDome
Mounting typeCeiling
Product colorWhite
Total megapixels2.1 MP
Maximum resolution1920 x 1080 pixels
Supported video modes1080p, 720p
Video formats supportedH.264, M-JPEG
Supported graphics resolutions320 x 240, 960 x 540, 1280 x 960, 1280 x 720 (HD 720), 1920 x 1080 (HD 1080), 640 x 480 (VGA)
Pan range-170 - 170 °
White balanceAuto, Daylight, Fluorescent, Lamp, Manual
Tilt angle range-90 - 10 °
Camera shutter speed0.0000625 - 1 s
Minimum illumination0.001 lx
Sensor typeCMOS
Optical sensor size1/3 \
Digital zoom12 x
Optical zoom20 x
Focus adjustment1.6 - 3.5
Focal length range4.7 - 94 mm
Security algorithmsEAP-MD5, EAP-TLS, EAP-TTLS, SSL/TLS
Password protection typeUser
Built-in HDDNo
Internal memory5 MB
Compatible memory cardsSD, SDHC, SDXC
Cabling technology10/100Base-T(X)
Supported network protocolsTCP/IP, UDP, HTTP, FTP, SNMP (MIB2), SMTP (Client), DHCP (Client), DNS (Client), ARP, ICMP, POP3, NTP, SMTP authentication, RTSP, WV-HTTP (Canon proprietary), ONVIF
Compliance industry standards802.3af PoE
InterfaceRJ-45
Ethernet LAN (RJ-45) ports1
Audio system2-way
Built-in microphone-
AC input voltage24 V
Power source typePoE
Power consumption (max)9.2 W
Operating temperature (T-T)-10 - 50 °C
Operating relative humidity (H-H)5 - 85 %
Weight and Dimensions IconWeight and Dimensions
Width132 mm
Height155 mm
Weight1140 g