6. DIAGNOSTIC OPERATION
6-1. To start the diagnostic program
1. Set the mode switch to “OFF” position.
2. Pressing the “FEED” button and turn the mode switch to “PRG” position.
3. Release the “FEED” button.
4. Input “9999900000” and press “ST” (“#2” key).
5. Diagnostic program is executed.
6-2. Check item
The following test can be checked in the diagnostic test.
1. Key code test
2. Switch status test
3. Individul function test.
6-3. Operation of each test
1. Key code test
When pressing a key, the machine displays
the following key code.
HARD KEY CODE TABLE
Hard key code
0 1 3
DISPLAY
“020” buttons are work for “#2” key.