Advanced programmings and registrations
To change the settings on departments
You can program several settings such as restricting entry digits, prohibiting mul-
tiple item registration, etc. on each department.
Sample Operation
Selections
Dept.1
?
Normal Dept. (A)
V
Maximum entry digits 4
(B)
Z
Single item sales Dept.
(C)
Dept.2
Z
Minus Dept. (A)
B
Maximum entry digits 5
(B)
?
Normal sales Dept. (C)
• Minus Dept. is a department that entered unit prices are registered as minus price and is used
for bottle return etc.
• Single item sales Dept. registers one item quickly just by pressing a Dept. key once and you
don’t need to press p.
Step Operation
1 Press Ck to set the register in the program mode.
Ck
2 Enter your selection A, B, and C refering the following tables then
press a Dept. key. The example on the right is setting Dept. 1 as
Normal Dept. (A) limiting 4 digits (B), and Single item sales Dept.
(C).
?VZa
A B C
3 The example on the right is setting Dept. 2 as Minus Dept. (A) limit-
ing 5 digits (B), and Normal sales Dept. (C).
ZB?s
A B C
4 Press k to complete the settings.
k
Selections
Normal Dept.
?
A
Minus Dept.
Z
Maximum seven digits manual price entry.
?
B
Maximum digit of manual price entry
Z to N
Prohibit manual price entry
< or >
Normal sales Dept
?
C
Single item Dept
Z
The default settings: ???