Step 6 Reconnect power cords to all power supplies and then allow the server to boot to standby power mode (indicated when
the front panel Power button LED lights amber).
Step 7 Fully power on the server by pressing the Power button.
Verify that the power LED on the front of the CPU module returns to solid green.
Note
Replacing Front-Loading SAS/SATA Drives
You do not have to shut down the server or drive to replace SAS/SATA hard drives or SSDs because they
are hot-swappable.
Note
Front-Loading SAS/SATA Drive Population Guidelines
The front drives in the server are installed into three removable drive bay modules.
Figure 19: Drive Bay Numbering
SAS/SATA/NVMe drive bay modules (UCSC-C480-8HDD):
Left drive bay module: Bays 1, 2, 7, 8 support SAS/SATA or NVMe drives; bays 3, 4, 5, 6 support
SAS/SATA drives only.
Front NVMe drives are not supported in a system with only one CPU module.
Note
Center drive bay module: Bays 9, 10, 15, 16 support SAS/SATA or NVMe drives; bays 11, 12, 13,
14 support SAS/SATA drives only.
Right bay module: Bays 17, 18, 23, 24 support SAS/SATA or NVMe drives; bays 19, 20, 21, 22
support SAS/SATA drives only.
Cisco UCS C480 M5 Server Installation and Service Guide
47
Maintaining the Server
Replacing Front-Loading SAS/SATA Drives

Table of Contents

Other manuals for Cisco UCS C480 M5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco UCS C480 M5 and is the answer not in the manual?

Cisco UCS C480 M5 Specifications

General IconGeneral
BrandCisco
ModelUCS C480 M5
CategoryServer
LanguageEnglish

Related product manuals