[SM-P00081-A]
16
3
OPERATION
N4E0-T7EC2, N4E0-T7ECT2 (32-point output)
< Standard wiring>
● Single solenoid valve:
Solenoid
Output No
s1 s2 s3 s4 s5 s6 s7 s8 s9 s10 s11 s12 s13 s14 s15 s16 s17 s18 s19 s20 s21 s22 s23 s24 s25 s26 s27 s28 s29 s30 s31 s32
Valve No.
1a 2a 3a 4a 5a 6a 7a 8a 9a 10a 11a 12a 13a 14a 15a 16a 17a 18a 19a 20a 21a 22a 23a 24a 25a 26a 27a 28a 29a 30a 31a 32a
● Double solenoid valve:
Solenoid
Output No
s1 s2 s3 s4 s5 s6 s7 s8 s9 s10 s11 s12 s13 s14 s15 s16 s17 s18 s19 s20 s21 s22 s23 s24 s25 s26 s27 s28 s29 s30 s31 s32
Valve No.
1a 1b 2a 2b 3a 3b 4a 4b 5a 5b 6a 6b 7a 7b 8a 8b 9a 9b 10a 10b 11a 11b 12a 12b 13a 13b 14a 14b 15a 15b 16a 16b
● Mixed (both single and double solenoid valves are mounted) (example):
Solenoid
Output No
s1 s2 s3 s4 s5 s6 s7 s8 s9 s10 s11 s12 s13 s14 s15 s16 s17 s18 s19 s20 s21 s22 s23 s24 s25 s26 s27 s28 s29 s30 s31 s32
Valve No.
1a 2a 3a 3b 4a 4b 5a 6a 7a 7b 8a 9a 10a 10b 11a 11b 12a 13a 14a 14b 15a 15b 16a
<Double wiring>
● Single solenoid valve:
Solenoid
Output No
s1 s2 s3 s4 s5 s6 s7 s8 s9 s10 s11 s12 s13 s14 s15 s16 s17 s18 s19 s20 s21 s22 s23 s24 s25 s26 s27 s28 s29 s30 s31 s32
Valve No.
1a
-
2a
-
3a
-
4a
-
5a
-
6a
-
7a
-
8a
-
9a
-
10a
-
11a
-
12a
-
13a
-
14a
-
15a
-
16a
-
● Double solenoid valve:
Solenoid
Output No
s1 s2 s3 s4 s5 s6 s7 s8 s9 s10 s11 s12 s13 s14 s15 s16 s17 s18 s19 s20 s21 s22 s23 s24 s25 s26 s27 s28 s29 s30 s31 s32
Valve No.
1a 1b 2a 2b 3a 3b 4a 4b 5a 5b 6a 6b 7a 7b 8a 8b 9a 9b 10a 10b 11a 11b 12a 12b 13a 13b 14a 14b 15a 15b 16a 16b
● Mixed (both single and double solenoid valves are mounted) (example):
Solenoid
O
utput No
s1 s2 s3 s4 s5 s6 s7 s8 s9 s10 s11 s12 s13 s14 s15 s16 s17 s18 s19 s20 s21 s22 s23 s24 s25 s26 s27 s28 s29 s30 s31 s32
Valve No.
1a
-
2a
-
3a 3b 4a 4b 5a
-
6a
-
7a 7b 8a
-
9a
-
10a
-
11a 11b 12a 12b 13a
-
14a
-
15a 15b 16a
-
The figure below is an example of mounting 16 stations of double-solenoid type solenoid valves.
For single-solenoid types, there is no solenoid on the b-side.
No.1
No.2
No.3
No.4
No.5
No.6
No.7
No.8
No.9
No.10
No.11
No.12
No.13
No.14
No.15
No.16
Manifold station no.

Questions and Answers: