INSTRUCTIONS FOR THE USER
28
MANUAL DRAIN
7 It is possible to empty the tank at any time of the day.
With the machine off, take out the overflow pipe from the tank and wait
until it is completely empty.
For machines equipped with drain pump it is possible to empty the tank
by starting the manual drain cycle during which only the drain pump is
active.
It is possible to perform this cycle only with the machine turned
on.
After having taken out the overflow pipe, press the "S9" button for 5
sec. The drain cycle will start.
??The display will show "C. .2." for the entire duration of the cycle
(2 min. and 20 sec.).
At the end of the cycle it is recommended to remove the filters of the tank
for cleaning and then put them back with the overflow pipe in their
positions.
READING THE TEMPERATURE
8. Pressing the "S10" button it is possible to view in sequence the
measured and programmed temperatures of the tank (t1) and of the boiler
(t2) for the selected cycle.
1. Pressing " S10" once the display shows the code "t.1. .";
2. pressing " S10" a second time shows the measured tank temperature
"x.x. .";
3. pressing " S10" a third time shows the programmed tank temperature
"x.x.P.";
4. Pressing " S10" a fourth time shows on the display the code "t.2. .";
5. pressing " S10" a fifth time shows the measured boiler temperature
" .x.x.";
6. pressing " S10" a sixth time shows the programmed boiler temp.
"P.x.x.";
7. pressing " S10" again returns to the starting state.
The operations described above can not be performed during a
cycle.