ENGLISH
72
GB
of water with temperatures close to freezing point, to avoid breakages of
the system. This is the reason why it is recommended to empty any elec-
tropump that is going to remain unused during the winter. However, this
system has a protection that prevents ice formation inside by activating the
electropump when the temperature falls to values close to freezing point.
In this way the water inside is heated and freezing prevented.
The Anti-Freeze protection works only if the system is regularly
fed: with the plug disconnected or in the absence of current the
protection cannot work.
However, it is advised not to leave the system full during long peri-
ods of inactivity: drain the system accurately through the drainage
cap (Fig.1 Face E) and put it away in a sheltered place.
4.1.4 - “BP1” Blockage due to fault of the internal pressure sensor
If the device detects a fault in the pressure sensor the pump remains
blocked and the error signal “BP1” is given. This status begins as soon as
the problem is detected and ends automatically when correct conditions
have been restored.
4.1.5 - “PB” Blockage due to supply voltage outside specications
This occurs when the allowed line voltage at the supply terminal assumes
values outside the specications. It is reset only automatically when the
voltage at the terminal returns within the allowed values.
4.1.6 - “SC” Blockage due to short circuit between the motor phases
The device is provided with protection against the direct short circuit which
may occur between the motor phases. When this blockage is indicated
you can attempt to restore operation by simultaneously holding down the +
and – keys, but this will not have any effect until 10 seconds have passed
since the moment the short circuit occurred.
4.2 - Manual reset of error conditions
In error status, the user can cancel the error by forcing a new attempt,
pressing and then releasing the + and – keys.
4.3 - Self-reset of error conditions
For some malfunctions and blockage conditions, the system attempts au-
tomatic self-reset.
The auto self-reset procedure concerns in particular:
“BL” Blockage due to water lack
“PB” Blockage due to line voltage outside specications
“OT” Blockage due to overheating of the power stages
“OC” Blockage due to motor overload
“BP” Blockage due to fault of the pressure sensor
For example, if the system is blocked due to water lack, the device auto-
matically starts a test procedure to check whether the machine is really
left denitively and permanently dry. If during the sequence of operations
an attempted reset is successful (for example, the water comes back), the
procedure is interrupted and normal operation is resumed.
Table 21 shows the sequences of the operations performed by the device
for the different types of blockage.
Automatic resets of error conditions
Display indica-
tion
Description Automatic reset sequence
BL
Blockage due to water
lack
- One attempt every 10 minutes for a
total of 6 attempts
- One attempt every hour for a total of
24 attempts
- One attempt every 24 hours for a total
of 30 attempts

Table of Contents

Other manuals for DAB E.sybox

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DAB E.sybox and is the answer not in the manual?

DAB E.sybox Specifications

General IconGeneral
BrandDAB
ModelE.sybox
CategoryWater Pump
LanguageEnglish

Related product manuals