EasyManuals Logo
Home>DAB>Water Pump>E.sybox

DAB E.sybox User Manual

DAB E.sybox
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #52 background imageLoading...
Page #52 background image
ENGLISH
108
GB
The e.sybox used as the Slave must have a rmware version of 4.00 or
more. In the case of e.sybox 30/50 it is always possible.
The rmware version of the Master must be greater or the same as the
version of the Slave.
It is necessary to have associated the devices with each other.
If several e.sybox units have to be updated the procedure must be re-
peated each time.
Procedure
1. Associate the devices (see par. 7.5.5). A pop-up will appear on the
display of both e.sybox units saying:
Where in place of x.y the rmware version of the e.sybox will appear.
2. Press the [+] key on both machines.
3. Wait for the update to be successfully completed and for both ma-
chines to restart.
Problem solving
If the update has not been successful, the machine that you were trying to
update (Salve) goes into an inconsistent status which does not allow a new
automatic update. In this case the updating procedure must be performed
manually.
11.2.1.3 - Semiautomatic updating
Not contemplated in the case of e.sybox 30/50, while in the case of e.sy-
box the conditions below apply.
Requirements
It is carried out between 2 e.sybox units at a time.
The e.sybox used as the Master must have a rmware version of 4.00
or more.
The e.sybox used as the Slave must have a rmware version of less
than 4.00.
Association between different
rmware version
V x.y
Press + to update
It is necessary to have associated the devices with each other.
If several e.sybox units have to be updated the procedure must be re-
peated each time.
Procedure
1. Associate the devices.
The e.sybox with the older rmware (Slave) will show the screen:
The e.sybox with rmware version of 4.00 or more will show the screen:
Where in place of x.y the rmware version of the e.sybox will appear.
2. Press the [+] key on the Master machine (the one with rmware ver-
sion of 4.00 or more).
3. Switch off the electric power supply to the Slave e.sybox and wait for
the display to switch off.
4. On the Slave e.sybox, supply power by holding down simultaneously
the [MODE] and [-] keys until the update screen appears.
5. Wait for the update to be successfully completed and for both ma-
chines to restart.
Problem solving
If the update has not been successful, the machine that you were trying
to update (Slave) goes into an inconsistent status which does not allow a
new semiautomatic update. In this case the updating procedure must be
performed manually.
Wait
Association between different
rmware version
V x.y
Press + to update

Table of Contents

Other manuals for DAB E.sybox

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DAB E.sybox and is the answer not in the manual?

DAB E.sybox Specifications

General IconGeneral
BrandDAB
ModelE.sybox
CategoryWater Pump
LanguageEnglish

Related product manuals