4 | Quick guide
User reference guide
12
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620245-1 – 2020.06
4.2 Space heating/cooling
To turn room temperature control ON or OFF
1 Go to [C.1]: Operation > Room.
Operation
Room
Space heating/cooling
On
On
C.1
2 Set operation to On or Off.
To turn space heating/cooling operation ON or OFF
NOTICE
Room frost protection. Even if you turn OFF space heating/cooling operation ([C.2]:
Operation > Space heating/cooling), room frost protection –if enabled– will
remain active.
NOTICE
Water pipe freeze prevention. Even if you turn OFF space heating/cooling operation
([C.2]: Operation > Space heating/cooling), water pipe freeze prevention –if
enabled– will remain active.
1 Go to [C.2]: Operation > Space heating/cooling.
Operation
Space heating/cooling
Tank
Off
On
On
Room
C.2
2 Set operation to On or Off.
To change the desired room temperature
During room temperature control, you can use the room temperature setpoint
screen to read out and adjust the desired room temperature.
1 Go to [1]: Room.
Room
1

Table of Contents

Other manuals for Daikin Altherma 3 M

Question and Answer IconNeed help?

Do you have a question about the Daikin Altherma 3 M and is the answer not in the manual?

Daikin Altherma 3 M Specifications

General IconGeneral
Heating Capacity4.0 - 16.0 kW
Cooling Capacity3.5 - 14.0 kW
RefrigerantR-32
Energy Efficiency ClassA+++
Operating Range (Heating)-25°C to 35°C
Operating Range (Cooling)10°C to 46°C
TypeAir to Water Heat Pump
Sound Power Level58-65 dB(A) (depending on model)