EasyManuals Logo

Daikin VRV Service Manual

Daikin VRV
255 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #71 background imageLoading...
Page #71 background image
Si30-408
Troubleshooting 67
D. Troubleshooting
D. TroubleshootingD. Troubleshooting
D. Troubleshooting
1. For Troubleshooting ..............................................................................68
2. Check Items before Troubleshooting ....................................................69
2.1 Check Items on Operation Condition (Essential Items as a Minimum) ..69
2.2 Check for Malfunction in Cooling Operation...........................................70
2.3 Check for Malfunction in Heating Operation...........................................71
3. Method of Troubleshooting ...................................................................72
3.1 Excessive / Insufficient Charging of Refrigerant.....................................72
3.2 Abnormal Judgment for Various Sensors...............................................75
3.3 Structure and Operation of Electronic Expansion Valve ........................83
3.4 Structure and Movements of Four-way Valve ........................................85
3.5 Structure and Operation of Solenoid Valve ............................................87
3.6 Structure and Operation of Two-way Solenoid Valve.............................88
3.7 Check on Outdoor Fan Motor.................................................................89
3.8 Diagnosis on Malfunction Code of Inverter System ...............................90
3.9 Diagnosis on Transmission System Malfunction....................................93
4. Malfunction Tree Analysis (FTA)...........................................................96
4.1 Actuation of Freeze-up Prevention Control of Indoor Unit......................97
4.2 Actuation of HPS in Heating Operation ..................................................98
4.3 Abnormal Discharge Pipe Temperature in Cooling Operation ...............99
4.4 Water Leakage from Indoor Unit ..........................................................100
4.5 Defective Lubrication of Compressor ...................................................101
5. List of Malfunction Code......................................................................102
6. Operating Condition Check Sheet.......................................................108

Table of Contents

Other manuals for Daikin VRV

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin VRV and is the answer not in the manual?

Daikin VRV Specifications

General IconGeneral
BrandDaikin
Energy EfficiencyHigh
ControlCentralized and individual zone control
Inverter TechnologyYes
TypeVariable Refrigerant Volume (VRV)
Cooling CapacityVaries by model
Heating CapacityVaries by model
RefrigerantR-32 or R-410A
ApplicationCommercial buildings, large residential spaces
SEERVaries by model
HSPFVaries by model
EERVaries by model
COPVaries by model
Sound LevelVaries by model
Indoor Unit Optionswall-mounted, ducted

Related product manuals