5.3 Parameter List
5.3.1 Introduction
Changes during operation
True means that the parameter can be changed while the
frequency converter is in operation. False means that the
frequency converter must be stopped before a change can
be made.
4 set-up
All set-ups: The parameter can be set individually in each
of the 4 set-ups, for example, 1 single parameter can have
4
dierent data values.
1 set-up: The data value is same in all set-ups.
Data
type
Description Type
2 Integer 8 Int8
3 Integer 16 Int16
4 Integer 32 Int32
5 Unsigned 8 Uint8
6 Unsigned 16 Uint16
7 Unsigned 32 Uint32
9 Visible string VisStr
33 Normalized value 2 bytes N2
35 Bit sequence of 16 boolean variables V2
54 Time dierence w/o date TimD
Table 5.2 Data Type
5.3.2 Parameter List
Parameter Default value 4 set-up
Change during
operation
Conversion
index
Type
Parameter 8-01 Control Site [0] Dig. & ctrl. word All set-ups TRUE – Uint8
Parameter 8-02 Control Source – All set-ups TRUE – Uint8
Parameter 8-03 Control Timeout
Time
1 1 set-up TRUE -1 Uint16
Parameter 8-04 Control Timeout
Function
[0] O 1 set-up TRUE – Uint8
Parameter 8-07 Diagnosis Trigger [0] Disable 1 set-up TRUE – Uint8
Parameter 8-10 Control Word Prole [0] FC prole All set-ups TRUE – Uint8
Parameter 8-14 Congurable
Control Word CTW
[1] Prole default All set-ups TRUE – Uint8
Parameter 8-19 Product Code – 1 set-up TRUE 0 Uint32
Parameter 8-30 Protocol [0] FC 1 set-up TRUE – Uint8
Parameter 8-31 Address 1 1 set-up TRUE 0 Uint8
Parameter 8-32 Baud Rate [2] 9600 Baud 1 set-up TRUE – Uint8
Parameter 8-33 Parity / Stop Bits
[0] Even Parity, 1 Stop
Bit
1 set-up TRUE – Uint8
Parameter 8-35 Minimum Response
Delay
0.010 1 set-up TRUE -3 Uint16
Parameter 8-36 Maximum Response
Delay
– 1 set-up TRUE -3 Uint16
Parameter 8-37 Maximum Inter-
char delay
0.025 s 1 set-up TRUE -3 Uint16
Parameter 8-42 PCD Write Congu-
ration
[0] None 2 set-ups TRUE – Uint8
Parameter 8-43 PCD Read Congu-
ration
[0] None 1 set-up TRUE – Uint8
Parameter 8-50 Coasting Select [3] Logic OR All set-ups TRUE – Uint8
Parameter 8-51 Quick Stop Select [3] Logic OR All set-ups TRUE – Uint8
Parameter 8-52 DC Brake Select [3] Logic OR All set-ups TRUE – Uint8
Parameter 8-53 Start Select [3] Logic OR All set-ups TRUE – Uint8
Parameter 8-54 Reversing Select [3] Logic OR All set-ups TRUE – Uint8
Parameter 8-55 Set-up Select [3] Logic OR All set-ups TRUE – Uint8
Parameter 8-56 Preset Reference
Select
[3] Logic OR All set-ups TRUE – Uint8
Parameter 8-57 Prodrive OFF2
Select
[3] Logic OR All set-ups TRUE – Uint8
Parameters Programming Guide