Table 6: Device Type Specifications
Device
type
Specifications
Additional information
Data
Value
TTL (A, B,
Z)
Signal level
0–5 V
Differential signals are preferred, but single signals are also supported. For single
signals, the trigger threshold is 0.33–0.4 times the encoder supply voltage.
Maximum res-
olution
65535
Maximum fre-
quency
750 kHz
HTL (A, B,
Z)
Signal level
0–24 V
Maximum res-
olution
65535
Maximum fre-
quency
500 kHz
SinCos
Signal level
1 V peak-
peak
Maximum res-
olution
65535
Maximum fre-
quency
750 kHz
SSI
Maximum res-
olution
32 bit
Maximum data
length
64 bit
Maximum
clock frequen-
cy
2 MHz
EnDat
Maximum res-
olution
32 bit
Both EnDat 2.1 and EnDat 2.2 are supported.
Maximum data
length
64 bit
Maximum
clock frequen-
cy
8.33 MHz
HIPER-
FACE DSL®
Maximum res-
olution
32 bit
Maximum data
length
64 bit
Baud rate
10 Mbps
BiSS
Maximum res-
olution
32 bit
Both BiSS B and BiSS C are supported.
Maximum data
length
64 bit
AQ390830267692en-000601 / 136R027316 | Danfoss A/S © 2023.06
Encoder/Resolver Installation and
Configuration
Functional Extension Options
Operating Guide

Other manuals for Danfoss iC7 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss iC7 Series and is the answer not in the manual?

Danfoss iC7 Series Specifications

General IconGeneral
BrandDanfoss
ModeliC7 Series
CategoryMedia Converter
LanguageEnglish

Related product manuals