Functions
Data
Maximum terminal load (DC-13) : Inductive load
24 V DC, 0.1 A
Minimum load
24 V DC, 10 mA
24 V AC, 20 mA
Rated number of cycles (@2 A resistive load)
400 000 switchings
Cable type
Cu, 75 °C (167 °F)
Cable size
Solid: 0.2–2.5 mm
2
(24–14 AWG)
Flexible: 0.2–2.5 mm
2
(24–14 AWG)
Flexible with ferrule, without plastic sleeve: 0.25–2.5 mm
2
(24–14 AWG)
Flexible without ferrule, with plastic sleeve: 0.25–2.5 mm
2
(24–14 AWG)
Maximum cable length
300 m (984 ft)
Maximum altitude
4400 m (14400 ft)
N O T I C E
The operating altitude sets requirements on voltages.
For the wiring diagrams for different operating altitudes, see 6.5.1 Wir-
ing Diagrams for Different Operating Altitudes.
Ambient temperature
-30 °C...60 °C (-22 °F...140 °F)
Weight
0.12 kg (0.26 lb)
Environment
Overvoltage category III/pollution degree 2
6.5 Setup and Connection Examples for Relay Option OC7R0
1 2 3 4 5 6 7 8
X101
(T2)
X102
(T5)
X103
(T8)
e30bk032.10
Illustration 25: Wiring Configuration for Relay Option OC7R0
AQ390830267692en-000601 / 136R0273 | 45Danfoss A/S © 2023.06
Relay Option Installation and
Configuration
Functional Extension Options
Operating Guide

Other manuals for Danfoss iC7 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss iC7 Series and is the answer not in the manual?

Danfoss iC7 Series Specifications

General IconGeneral
BrandDanfoss
ModeliC7 Series
CategoryMedia Converter
LanguageEnglish

Related product manuals