PVED-CLS soft-stop
Soft-stop can decrease flow sent from the electro-hydraulic valve the to cylinders when wheels are close
to end-stop to help prevent damage and jerk.
Example parameter settings
Parameter Conditions for value change
P3562 Distance from end-stop flow starts to decrease [0.1%]
P3566 Distance from end-stop flow stops decreasing [0.1%]
P3564 Max allowed flow at cylinder end-stop [0.1%]
Example of soft-stop flow limitation
Application Guide
PVED-CLS startup guide
Parameter setting
©
Danfoss | October 2018 AB285975085591en-000101 | 25