Page #20 background imageLoading...
Page #20 background image
Closed Center PVP
The basic Closed Center PVP inlet is intended for use with variable displacement pumps in applications
where a valve group with mechanically controlled work sections is desired, or where the pilot pressure to
the valve group is supplied externally.
The Closed Center PVP features:
Integrated LS pressure relief valve
Threaded ports for P/T/LS and M measuring gauge
Optional LS unloading valve, PVPX
Optional T0 facility and external T0 port
Closed center PVP schematic
LS
T
P
M
Technical specification for PVP
Max. P-port continuous Max. P-port intermittent Max. T-port static/
dynamic
Max. rated flow
350 [5076 psi] 400 bar [5800 psi] 25/40 bar [365/580 psi] 140 l/min [37 US gal/min]
Technical specification
Parameter Minimum Recommended range Maximum
Fluid temperature
-30°C [-22°F] 30 to 60°C [86 to 140°F] 90° [194°F]
Fluid viscosity
4 mm
2
/s [39 SUS] 12 to 75 mm
2
/s [65 to 347 SUS] 460 mm
2
/s [2128 SUS]
Fluid cleanliness
23/19/16 (according to ISO 4406)
Operating temperature
Ambient: -30 to 60°C [-22 to 140°F]
Technical Information
PVG 16 Proportional Valve Group
PVP Inlet Modules
20 |
©
Danfoss | December 2018 BC00000211en-000901

Table of Contents

Other manuals for Danfoss PVG 16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PVG 16 and is the answer not in the manual?

Danfoss PVG 16 Specifications

General IconGeneral
BrandDanfoss
ModelPVG 16
CategoryControl Unit
LanguageEnglish

Related product manuals