EasyManuals Logo
Home>Danfoss>Control Unit>PVG 16

Danfoss PVG 16 Technical Information

Danfoss PVG 16
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #59 background imageLoading...
Page #59 background image
PVLP Shock and Anti-Cavitation Valve
The PVLP shock and anti-cavitation valve will relieve a pressure peak to the internal tank galleries and will
furthermore suck oil from the tank to the work port to prevent cavitation. Pressure settings range: 32–400
bar [460–5801 psi].
The pressure setting of the PVLP must always be 20 bar [290 psi] higher than LS
A/B
setting in the same
module.
PVLP schematic
P109174
Port pressure
PVLP shock valve characteristics
(l/min)
[US gal/min]
P
Q
Q
(bar)
[psi]
20 40 60 80 100 120 140
5
10 15 20 25 30 35 40 45
400
350
300
250
200
150
100
50
0
5000
4000
3000
2000
1000
0
6000
0
0
Technical Information
PVG 16 Proportional Valve Group
PVB Basic Modules Accessories
©
Danfoss | December 2018 BC00000211en-000901 | 59