EasyManuals Logo
Home>Danfoss>Control Unit>PVG 16

Danfoss PVG 16 Technical Information

Danfoss PVG 16
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #79 background imageLoading...
Page #79 background image
PVEO Technical Data
Control Specifications
Description Type 12 V
DC
± 10% 24 V
DC
± 10%
Supply Voltage (U
DC
) Range 11 to 15 V
DC
12 to 30 V
DC
Max. ripple 5% 5%
Current Consumption Typical 320 mA 160 mA
Pilot pressure
Minimum Nominal Maximum
10.0 bar [145 psi] 13.5 bar [196 psi] 15.0 bar [218 psi]
Fluid consumption
Neutral/Locked position Actuating
0.4 l/min [0.11 US gal/min] 0.6 l/min [0.16 US gal/min]
Technical specification
Parameter Minimum Recommended range Maximum
Fluid viscosity
4 mm
2
/s [39 SUS] 12 to 75 mm
2
/s [65 to 347 SUS] 460 mm
2
/s [2128 SUS]
Fluid cleanliness
18/16/13 (according to ISO 4406)
Storage temperature
Ambient: -50 to 90°C [-58 to 194°F]
Operating temperature
Ambient: -30 to 60°C [-22 to 140°F]
LED characteristic
Color LED characteristic Description
Green constant Power ON
Part numbers for PVEO and PVEO-CI
Part number Type Connector Protection Class Voltage Interface
11106793
PVEO 1x4 DEUTSCH IP 65 12 V
DC
11106794
PVEO 1x4 DEUTSCH IP 65 24 V
DC
11124002
PVEO-CI 1x4 DEUTSCH IP 67 J1939/ISObus
11149443
PVEO-CI 1x4 DEUTSCH IP 67 CANopen
Technical Information
PVG 16 Proportional Valve Group
PVG 16 Actuation
©
Danfoss | December 2018 BC00000211en-000901 | 79

Table of Contents

Other manuals for Danfoss PVG 16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PVG 16 and is the answer not in the manual?

Danfoss PVG 16 Specifications

General IconGeneral
BrandDanfoss
ModelPVG 16
CategoryControl Unit
LanguageEnglish

Related product manuals