PVLA Suction Valve
The PVLA valve is an accessory available for PVB basic modules.
The PVLA will suck fluid from the tank to the work port to prevent cavitation by the 0.5 bar spring. The
plug will ensure that when using a single acting spool, all flow returning through the work port is led to
tank.
PVLA schematic
P109175
Port pressure
PVLP/PVLA suction valve characteristics
5 10 15 20 25 30 35 40 45 50 55 60 65
[l/min]
[US gal/min]
70 75 80
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
20
18
16
14
12
10
8
6
4
2
0
85 90 95 100
22 23 24 25 26
Q
28
26
24
22
P
P
200
160
120
80
40
0
280
240
320
400
360
0
[psi] [bar]
0
Q
105 110 115 120
27 28 29 30 31
PVLP
PVLA
Technical specification
Parameter Minimum Recommended range Maximum
Fluid temperature
-30°C [-22°F] 30 to 60°C [86 to 140°F] 90° [194°F]
Fluid viscosity
4 mm
2
/s [39 SUS] 12 to 75 mm
2
/s [65 to 347 SUS] 460 mm
2
/s [2128 SUS]
Fluid cleanliness
23/19/16 (according to ISO 4406)
Operating temperature
Ambient: -30 to 60°C [-22 to 140°F]
PVLA suction valve part number
PVLA suction valve Plug
157B2001 157B2002
Technical Information
PVG 16 Proportional Valve Group
PVB Basic Modules Accessories
©
Danfoss | December 2018 BC00000211en-000901 | 61

Table of Contents

Other manuals for Danfoss PVG 16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PVG 16 and is the answer not in the manual?

Danfoss PVG 16 Specifications

General IconGeneral
BrandDanfoss
ModelPVG 16
CategoryControl Unit
LanguageEnglish

Related product manuals