In this parameter, Data Change Mode is not exited au-
tomatically (after time out).
Local reference cannot be set via the serial communi-
cation port.
Warning: Since the value set is retained
after the power has been cut, the motor
may start without warning when the power
is reinstated; if parameter 019 is changed
to Auto restart, use saved ref. [0].
004 Active Setup
(ACTIVE SETUP)
Value:
Factory Setup (FACTORY SETUP) [0]
Setup 1 (SETUP 1) [1]
Setup 2 (SETUP 2) [2]
Setup 3 (SETUP 3) [3]
Setup 4 (SETUP 4) [4]
MultiSetup (MULTI SETUP) [5]
Function:
This parameter defines the Setup number to control
the functions of the frequency converter.
All parameters can be programmed in four individual
parameter Setups, Setup 1 - Setup 4. In addition, there
is a Factory Setup, which cannot be modified.
Description of choice:
Factory Setup [0] contains the data set at the works.
Can be used as a data source if the other Setups are
to be returned to a known state.
Parameter 005 and 006 allow copying from one Setup
to one or all the other Setups.
Setups 1-4 [1]-[4] are four individual Setups that can
be selected individually.
Multi-Setup [5] is used by remote-switching between
Setups. Terminals 16/17/29/32/33 as well as the serial
communication port can be used for switching be-
tween Setups.
005 Programming Setup
(EDIT SETUP)
Value:
Factory Setup (FACTORY SETUP) [0]
Setup 1 (SETUP 1) [1]
Setup 2 (SETUP 2) [2]
Setup 3 (SETUP 3) [3]
Setup 4 (SETUP 4) [4]
Active Setup (ACTIVE SETUP) [5]
Function:
The choice is of the Setup in which programming
(change of data) is to occur during operation (applies
both via the control panel and via the serial communi-
cation port). The 4 Setups can be programmed inde-
pendently of the Setup selected as the active Setup
(selected in parameter 004).
Description of choice:
The Factory Setup [0] contains the data set at the
works and can be used as a data source if the other
Setups are to be returned to a known state.
Setups 1-4 [1]-[4] are individual Setups which can be
used as required. They can be programmed freely, re-
gardless of the Setup selected as the active Setup and
thus controlling the functions of the adjustable fre-
quency drive.
NOTE
If a general change of data or a copying to
the active Setup is effected, this immedi-
ately affects the functioning of the unit.
006 Copying of Setups
(SETUP COPY)
Value:
No copying (NO COPY) [0]
Copy to Setup 1 from # (COPY TO SETUP 1) [1]
Copy to Setup 2 from # (COPY TO SETUP 2) [2]
Copy to Setup 3 from # (COPY TO SETUP 3) [3]
Copy to Setup 4 from # (COPY TO SETUP 4) [4]
Copy to Setup all from # (COPY TO ALL) [5]
# = the Setup selected in parameter 005
VLT
®
5000 Series
= factory setting, () = display text, [] = value for use in communication via serial communication port
80 MG.51.C5.22 - VLT
p
is a registered Danfoss trademark.

Table of Contents

Other manuals for Danfoss VLT 5003

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 5003 and is the answer not in the manual?

Danfoss VLT 5003 Specifications

General IconGeneral
BrandDanfoss
ModelVLT 5003
CategoryDC Drives
LanguageEnglish

Related product manuals